Medtronic Guardian 4 Sensor for the MiniMed 780G system - Box of 5
Available Online Only
Medtronic Guardian 4 Sensor for the MiniMed 780G system - Box of 5
- Product type: Therapeutic good — medical device included on the Australian Register of Therapeutic Goods (ARTG)
- Used for: a wearable subcutaneous continuous-glucose-monitor (CGM) sensor used as part of an insulin-delivery or self-monitoring system for people with diabetes
- Australian sponsor: Medtronic Australasia Pty Ltd
- Pack size: 5 sensors per box
- Last reviewed: 29 May 2026
Product specification
| Product type | Medical Device — included on ARTG |
|---|---|
| Device class | Class IIb (continuous glucose monitor sensor) |
| Australian sponsor | Medtronic Australasia Pty Ltd |
| Dosage form | Subcutaneous wearable CGM sensor (single-use) |
| Route of administration | Interstitial (subcutaneous insertion) |
| Pack size | 5 sensors per box |
| Intended purpose | Subcutaneous continuous-glucose-monitor (CGM) sensor for use with the Medtronic MiniMed 780G automated insulin-delivery system in people with diabetes who require insulin therapy. Each sensor is worn for up to 7 days. |
| Storage | Store below 30°C in a dry place, away from direct sunlight. Keep out of reach of children. |
About this product
Continuous glucose sensor for the Medtronic MiniMed 780G automated insulin delivery system.
Medtronic Guardian 4 Sensor for the MiniMed 780G system - Box of 5 is a wearable subcutaneous continuous-glucose-monitor (CGM) sensor used as part of an insulin-delivery or self-monitoring system for people with diabetes. Supplied in Australia by Medtronic Australasia Pty Ltd. Use it in accordance with the carton instructions and your healthcare professional's advice.
Key features
- 7-day wear time per sensor
- Compatible with the Medtronic MiniMed 780G AID system, which automates insulin delivery based on real-time glucose data
- Real-time glucose readings every 5 minutes, with predictive low- and high-glucose alerts
- Calibration-free for the full wear period (per the Medtronic User Guide)
- Waterproof — can be worn while swimming, showering and bathing
- Discreet — wears on the upper arm, abdomen or buttock
- Subsidised by the National Diabetes Services Scheme (NDSS) for eligible Australians
- Sponsored in Australia by Medtronic Australasia Pty Ltd
What makes Medtronic Guardian 4 Sensor for the MiniMed different
The Guardian 4 sensor is the current-generation CGM sensor designed specifically to integrate with Medtronic's MiniMed 780G automated insulin delivery (AID) system — a closed-loop pump-and-sensor pairing that automatically adjusts basal insulin delivery and gives correction boluses based on the real-time glucose trend. Unlike standalone CGMs that just display data, the Guardian 4 sensor is the closed-loop input that drives the 780G's algorithm. This is the technology most Australian endocrinologists currently recommend for adults and children with type 1 diabetes seeking the tightest reasonable glycaemic control without manual sensor calibration.
Who is it for?
- Adults and children with type 1 diabetes who use (or are about to start) the Medtronic MiniMed 780G insulin pump
- Users transitioning from manual fingerstick monitoring to continuous glucose monitoring
- Pregnant women with insulin-treated diabetes (under their endocrinologist's direction)
- NDSS-registered users seeking subsidised access to CGM technology
What's in the pack
5 × Guardian 4 CGM sensors, each in a sterile pouch with an integrated inserter. Each sensor is single-use for up to 7 days of wear.
Pharmacist usage tip
Insert a new sensor every 7 days following the User Guide. Rotate insertion sites between the upper arm, abdomen and buttock to reduce skin irritation. The 780G pump must be paired with the sensor transmitter — not all Medtronic pumps are 780G-compatible, so check your current pump model with your CDE before purchasing replacement sensors.
Intended purpose
Subcutaneous continuous-glucose-monitor (CGM) sensor for use with the Medtronic MiniMed 780G automated insulin-delivery system in people with diabetes who require insulin therapy. Each sensor is worn for up to 7 days.
Directions for use
Follow the manufacturer's User Guide for sensor insertion, transmitter pairing, and warm-up. Each sensor is single-use for the wear time stated on the carton. Rotate insertion sites with every change as directed.
Warnings and important information
- Follow the manufacturer's User Guide for activation, insertion and wear-time limits.
- Single-use only — do not re-insert a removed sensor or re-use a removed pod.
- Rotate insertion sites with every change to reduce the risk of skin irritation.
- Always carry backup fingerstick supplies for confirming readings if the device alarms or fails.
- Keep out of reach of children when not in use.
Storage
Store the unopened pack in a clean, dry place at room temperature. Keep away from extreme heat, direct sunlight, and moisture. Keep out of reach of children. Do not use after the expiry date printed on the pack or sterile barrier.
Frequently asked questions
What is Medtronic Guardian 4 Sensor for the MiniMed used for?
Medtronic Guardian 4 Sensor for the MiniMed is a wearable subcutaneous continuous-glucose-monitor (CGM) sensor used as part of an insulin-delivery or self-monitoring system for people with diabetes. It is supplied in Australia by Medtronic Australasia Pty Ltd. Refer to your pharmacist or doctor for advice on whether the product is suitable for you.
How do I use Medtronic Guardian 4 Sensor for the MiniMed?
Follow the manufacturer's User Guide for sensor insertion, transmitter pairing, and warm-up. Each sensor is single-use for the wear time stated on the carton. Rotate insertion sites with every change as directed.
How long does each Medtronic Guardian 4 Sensor for the MiniMed last?
Refer to the Product Specification above and the manufacturer's User Guide for the exact wear time. Most CGM sensors are worn for 7 to 14 days and most insulin pump pods are worn for up to 72 hours.
Is Medtronic Guardian 4 Sensor for the MiniMed waterproof?
Most wearable diabetes devices supplied through Australian pharmacies are water-resistant for showering, bathing and swimming for limited periods. Refer to the manufacturer's User Guide for the exact rating (IP67, IPX8, etc.) and depth/time limit.
Is Medtronic Guardian 4 Sensor for the MiniMed funded by the NDSS?
The National Diabetes Services Scheme subsidises many continuous glucose monitoring (CGM) and insulin pump consumables for eligible Australians, particularly people with type 1 diabetes. Check your NDSS eligibility through your endocrinologist or diabetes educator.
What happens if my sensor or pod fails before its wear time is up?
Contact the manufacturer's Australian support line — the contact number is in the User Guide. Most manufacturers replace faulty sensors or pods if reported within the warranty period and the failure is not user-caused.
Where is it manufactured?
Medtronic Guardian 4 Sensor for the MiniMed is supplied in Australia by Medtronic Australasia Pty Ltd.
This information is general in nature and is not a substitute for professional medical advice. If you have questions about whether Medtronic Guardian 4 Sensor for the MiniMed is right for you, speak with your pharmacist or doctor. For 24-hour health advice in Australia, call Healthdirect on 1800 022 222. For poisoning enquiries, call the Poisons Information Centre on 13 11 26.
Sources
- Australian Register of Therapeutic Goods (ARTG) — entry for this product. tga.gov.au/resources/artg
- Therapeutic Goods Administration — Permissible Indications Determination and Therapeutic Goods (Therapeutic Goods Advertising Code) Instrument 2021. tga.gov.au
- Healthdirect Australia — general consumer health information. healthdirect.gov.au
- Manufacturer carton and Consumer Medicine Information (where supplied).
ALWAYS READ THE LABEL ON THE PRODUCT AND FOLLOW THE DIRECTIONS FOR USE UNLESS DIRECTED BY YOUR HEALTHCARE PROFESSIONAL.
INFORMATION DISCLAIMER
All information supplied has no warranty whatsoever. Information and statements are not intended to diagnose, treat, cure, or prevent any disease. No warranty is made that any information on or linked to this Site is complete and/or accurate. All information contained on the Site, including information relating to medical and health conditions, products and treatments, is for informational purposes only. It is often presented in summary or aggregate form;
Professional advice is required for each particular illness, disease, infection, injury or other medical condition and for dosages of the pharmaceutical product supplied via this Site. This information is not to be taken as any sort of medical advice whatsoever. You take full and total responsibility for what you do with this information, and any resulting outcomes from your actions; and
The information contained in this Site is not intended nor is it implied to be a substitute for professional medical advice or any information contained on or in any product packaging or labels. Always seek the advice of your Pharmacist, General Practitioner, other medical practitioner or qualified health provider when starting any new medical treatment, continuing with medical treatment or with any questions you may have regarding yours or any other party's medical condition. Nothing contained in the service is intended to be or should be taken for medical diagnosis or treatment.
(Product SKU 125377)
| SKU | 125377 |
| Barcode # | 0763000737245 |
| Shipping Cubic | 0.002297000m3 |
Be The First To Review This Product!
Help other David Jones Pharmacy Online users shop smarter by writing reviews for products you have purchased.